Redring 620 用户手册

下载
页码 12
 
a) Water too HOT 
Water flow restricted by blockage in filter of 
solenoid valve. Switch off water and undo plastic 
nut on elbow, loosen brass nut to swing elbow 
away from solenoid. Remove filter in solenoid with 
long nosed pliers and flush clean. 
 
b) Water too COLD 
Check circuit through thermal cut-out 
Check circuit through microswitch on the pressure 
switch 
Check each element circuit. 
Check tightness of electrical connections. 
 
c) Water leaks from burst pressure relief 
valve 
Check for cause of high pressure and remove it. 
i.e. Blockage on outlet or blocked spray plate. 
Replace the pressure relief disc. 
 
d) Water does not flow when Knob “A” is 
rotated (when  button “C” is pressed - 
620 only) 
Check the circuit through the solenoid coil. 
Check circuit through mini microswitch (push switch 
– 620 only) 
Possible timer PCB fault (620 only). If defective, 
then replace. 
Power supply not reaching shower. 
 
Installation instructions 
 
Check that the electrical rating shown on the shower matches the mains supply.  
 
A competent installer must undertake all installations. If in any doubt, advice and 
assistance should be sought from a qualified plumber and/or electrician. Installations and 
wiring must conform to current IEE regulations (UK) BS7671 
 
WARNING! DO NOT INSTALL THIS SHOWER IN A ROOM WHERE IT MAY BE SUBJECT TO 
FREEZING 
 
We recommend that the installation be done in the following sequence. 
a)  Fixing the shower to the wall 
b) Plumbing 
c) Electrical connections 
 
a)  Fixing the shower to the wall 
 
1.  Position the riser rail at the height recommended in 
diagram 5 and mark its position. 
 
2.  Position the heater so the sides of the unit are vertical 
and the top is level with, or up to 0.6 metres (2ft) 
maximum below the top of the riser rail
. Choose a flat 
piece of wall to avoid the possibility of distorting the back 
plate thus making the front cover a poor fit 
 
3.  Adjust the positions to get the most convenient 
arrangement taking the following into account. 
 
a)  The possible need to use the handset over the sink 
for hair washing etc. 
 
b) The 
heater 
must not be mounted in the direct spray 
from the showerhead. 
 
 
Diagram 5