Acnodes FPC-8057 用户手册

下载
页码 57
FPC-8057 User’s Manual 
FUSE Replacement: 
The fuse use on FPC-8057 is: 
BUSSMANN 
Fast Acting, Glass Tube 
Rating: 250VAC, 1A Size: 
5x20mm 
Warning: 
Make sure the power off before replace the fuse. Do 
not replace the fuse with a different rating fuse. 
1. 
2. 
2.2.2 Grounding 
Requirements 
Chassis ground must be used. DC ground is not directly coupled to Earth 
ground internally. It is preferable not to ground DC negative return to 
chassis ground as poor site earths can introduce noise into a system, but if 
necessary an earth connection should be made, from the power supply 
return point to the central star earth point. Ground conductors should be as 
short and as large in size as possible. The conductors must always be 
large enough to carry the maximum short circuit current of the path being 
considered. Ground conductors should be connected to a tree from a 
central star earth ground point. This ensures that no ground conductor 
carries current from any other branch. 
11 
Installation Instructions