Smeg GKC64-3 用户手册

下载
页码 20
 
Instructions for the installer
 
 
33 
 
 
5.4 
Regulation for G25/25 mbar 
 
 
 
 
 The hob has been inspected for G25 (2L3B/P) at a pressure of 25 
mbar. To allow the unit to work with this type of gas, perform the same 
operations described in paragraph “5.3
Regulation for LPG”, but 
choose the nozzles and regulate the primary air for natural gas, as 
shown in the following table and in paragraph “5.5
Regulation of 
primary air”. After the regulations have been carried out, restore the 
seals with sealing wax or equivalent material. 
Burner 
Rated 
heating 
capacity 
Methaangas – G25 25 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
 (W 
Auxiliary 
1.05 
76 
400 
Semirapid 
1.7 
98 
450 
Rapid 
2.55 
120 
750 
Rapid large 
3.3 
132 
750 
Fish pan 
2.9 
126 
950 
Ultra rapid 
4.1 
150 
1400