Smeg GKC64-3 用户手册

下载
页码 20
Instructions for the installer
 
 
 
31 
 
 
5  ADAPTATION TO DIFFERENT TYPES OF GAS 
 
  Before performing any cleaning or maintenance work, disconnect the 
appliance from the electrical socket. 
 
  The hob has been inspected for G25 (2L3B/P) natural gas at a 
pressure of 25 mbar. For functioning with other types of gas the 
nozzles must be replaced and the primary air adjusted. 
To replace the nozzles and regulate the burners, you have to remove 
the top as described in the following paragraph. 
 
 
5.1 
Removing the separable control panel
 
(models with 
separable control panel) 
  
1.
 
Remove the knobs and the knob 
guard tube “A” by pulling them up; 
2.
 
Use a crosshead screwdriver to 
remove the screws and the two 
cylindrical supports “B”; 
3.
 
Raise the left-hand side of the 
control panel slightly and shift it to 
the right to remove it completely; 
4.
 
In models with electric hotplate, the 
body of the pilot light has to be 
removed to free the control panel; 
 
  
 
 
 
5.2 
Removing the hob
 
(models with integrated control 
panel) 
 
 
 
 
 
1.
 
Remove the knobs, the 
griddles, the burner caps, the 
flame caps and the two rear 
plugs; 
2.
 
Remove the screws “A” which 
fix the burner supports; 
3.
 
Raise the hob, sliding it off the 
ignition plugs and/or the 
thermocouples and the gas 
tap rods; 
 
 
 
 
5.3 
Regulation for LPG 
 
 
 
 
 Check that the connection has been made as described in the “Gas 
connection” section. 
Undo the screw “D” and push the air regulator “C” fully down. Use a 
spanner to remove the nozzles “B” and fit those of suitable type