SERVICE TOOLS
 
This function allows the testing of individual com-
ponents and the ability to check switches for proper 
function. This function also tests the Soft Heat server's 
status on the brewer (in place or removed), and the 
funnel sensor coil's frequency (diagnostic tool for 
troubleshooting purposes only).
Testing individual components (outputs):
  This will allow the operator to test the operation 
of individual components and outputs of the brewer.  
The components that can be individually tested are as 
follows:
SINGLE Brewers
Brew Valve
Bypass Valve
Funnel Lock (Optional)
Server
Refill Valve
Tank Heaters
Heater Contactor
DUAL Brewers 
Left Brew Valve
Left Bypass
Left Funnel Lock
Left Server
Right Brew Valve
Right Bypass
Right Funel Lock
Right Server
Refill Valve
Tank Heaters
Heater Contactor
PROGRAMMING THE BREWER (cont.)
Procedure to test components (outputs):
1.  Place brew funnel(s) into rails on the brewer (both 
sides on DUAL brewers).
2.  Place a Soft Heat server(s) beneath the brew 
funnel(s).
3.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to press and release switch until SERVICE TOOLS 
appears. 
4. Press YES to run tests on various components 
and outputs within the brewer. Pressing NO will 
exit this function and advance to next function 
screen.
5.  The display should read TEST OUTPUTS.
6.  Press and release YES. The display should read: 
BREW VALVE on SINGLE brewers
 
LEFT BREW VALVE on DUAL brewers.
7.  To test BREW VALVE, press ON. If the brew valve 
is functional, water should run from the brewer 
(left side on DUAL brewers)
8. Press OFF to end flow of water.
9. Press NEXT to advance to the next component to 
be tested.
NOTE: To bypass testing any component, press NEXT 
to advance to the next one, without testing the previ-
ous component.
10.  To test BREW BYPASS on SINGLE brewers or LEFT 
BREW BYPASS on DUAL brewers, press ON. If the 
bypass valve is functional, water should run from 
the brew bypass (left side on DUAL brewers).
11. Press OFF to end flow of water.
12. Press NEXT to advance to the next component to 
be tested.
13. To test FUNNEL LOCK on SINGLE brewers or LEFT 
FUNNEL LOCK on DUAL brewers, press ON. If the 
funnel lock is functional, the lock will come down 
to hold the funnel in place.
14. Press OFF to retract the funnel lock.
15. Press NEXT to advance to the next component to 
be tested.
16. To  test  SERVER on SINGLE brewers or LEFT 
SERVER on DUAL brewers, press ON. If the server 
and the sensor are functional, the light on the lower 
right corner of the server will illuminate.
17. Press OFF to end testing of server.
18. Press NEXT to advance to the next component to 
be tested.
19. For DUAL brewers, follow steps 7 through 15 to 
test the right side components.
20. To test REFILL VALVE, press ON. If the refill valve 
is functional, the sound of the valve operating will 
be heard.
21. Press OFF to end testing of refill valve.
22. Press NEXT to advance to the next component to 
be tested.
23.  To test TANK HEATERS, connect a voltmeter across 
each of the tank heaters to check for voltage.
24. Press ON. The correct voltage should be present 
at the heater terminals.
25. Press OFF to end testing of the tank heaters.