repeatedly. 
change. 
After short 
time of 
operation, 
over load 
protection 
unit cuts off 
1.  The voltage is too high. 
2. Over load protection unit is not good, it 
jumps earlier. 
3. Starter contacting point is adhered. 
4. There is short circuit in compressor. 
5. There is mechanical problem in the 
compressor. 
6. Temperature around compressor is too 
high. 
1.  Supplement  a  stabilizer  and 
adjust its value to rated. 
2.  Change  over  load  protection 
unit. 
3.  Change starting relay. 
4.  Change compressor. 
5.  Change compressor. 
6.Increase heat radiation space. 
Too 
much 
noise 
when 
compressor 
runs 
1.  The floor is loose. 
2.  The  freezer  body is  not  stable  and in 
level. 
3.  When 
compressor 
runs, 
friction 
between tubes and freezer body causes 
resonance. 
4.  Compressor fixing screw is loose. 
5.  The  vibration  absorption  cushion  for 
compressor  fixing  is  too  tight,  or  too 
loose or ageing. 
6.  Compressor inside noise is too big or 
vibration  absorption  suspending  spring 
is broken. 
1.  Reinforce the floor. 
2.  Make the freezer body stable. 
 
3.  Move  the  tube  a  little  away  to 
avoid friction. 
 
4.  Make the screw tight. 
 
5.  Adjust  the  degree  of  tight  or 
loose 
of 
vibration 
absorption 
cushion, or change cushion. 
6.  Change compressor.   
There is no 
frost at 
evaporator 
1.  There is serious leakage of 
refrigerant. 
2.  There  is  dirt  blocked  the  capillary  or 
system. 
1.  Check  leakage,  make  welding 
repair, and fill refrigerant again. 
2.  Clean  the  capillary  or  change 
filter. 
Frost 
at 
evaporator  is 
not full 
1.  There is some leakage of refrigerant. 
2.  There is dirt block, but not serious. 
3.  Refrigeration quantity of compressor 
is reduced. 
1.  Check  leakage,  make  welding 
repair, and fill refrigerant again. 
2Clean the capillary and filter. 
3.Change compressor. 
Evaporator 
frosts too 
rapid, frost 
layer too thick 
or frozen to 
ice 
1.  Food put into freezer contains water. 
2.  Too much food has been stored. 
1.  Please  let  or  make  food  dry     
after cleaning, then store it. 
2.  Store  only  corrects  quantity  of 
food. 
Electricity 
leakage 
of 
freezer  body, 
you  will  feel 
tingle 
when 
touching 
by 
hand 
1.  Freezer body has not been connected 
to the ground. 
2. The compressor terminal contacts body 
shell and causes short circuit. 
3.  When  the  components  of  electrical 
system  get  wet,  insulation  ability  is 
dropped, electricity leaks. 
1.  Make  the  ground  connection  as 
stipulated. 
2.  Change compressor. 
3.  Check  carefully  step  by  step,  if 
insulation  is  seriously  damaged, 
please  change;  remove  wet  parts 
and  put  them  into  drying  box  to 
make them dry. 
Electricity 
leakage 
of 
fan 
1.  Environment  temperature  too  high  or 
insulation ability of insulator is dropped. 
2.  There  is  short  circuit  between  fan 
coils or the fan coil is burned. 
1.  Change fan. 
 
 
2.Change fan. 
Fan too noisy 
1.  The  blade  of  fan  is  blocked  or  fan 
supporter is loose. 
2.  The clearance of fan axle is too big. 
1.  Clear  obstacles  around  the  fan 
or tighten the supporter. 
2.  Change the fan. 