Installation Instructions
 3  INSTAll coNTRol SWITch 
(on some models)
Skip this step if there is no separate control switch.
connect Wire lead to control box
• Connect the mating wire ends.
• Place the adhesive wire clamps (provided) near 
the mating connector.
• Keep approximately 3"-long wire and attach  
the wire to the clamp with a wire tie. This will act 
as a strain relief.
• Drill a 1/2"-dia. hole into the desired location.  
Use the mounting bracket as a template to locate 
the hole accurately. Check for interference  
between the switch cover, adjacent objects  
and cooktop/vent overlaps.
• If switch is mounted into a tile surface, drill the hole 
between tiles. Use locally approved caulking to 
cover any gaps.
connect control Switch to Remote harness
• Thread the remote harness through the 1/2"-dia. 
hole and attach the harness connector to the 
remote connector.
• Remove the paper backing on the foam piece 
and mount the remote trim on the countertop 
such that the switch connectors stay located  
in the 1/2"-dia. hole.
• Stick adhesive wire clamp near the 1/2"-dia. hole 
and attach the loose wire with a wire tie.
     WARNING:
Disconnect electrical power from unit before  
beginning switch installation. Failure to do so could 
result in personal injury or damage to the electrical 
controls.
Determine the location for the control switch.  
The wiring lead is 68" long.
Control 
Box
1/2"-Dia.  
Hole
Foam Piece With Adhesive 
Mounting Surface
Remote Switch
Strain Relief  
(Adhesive wire clamp  
with tie)
Remote Harness
Remote Harness
Mating Connectors
Strain Relief  
(Adhesive wire clamp 
with tie)