Instructions for the installer
17
13.INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by competent persons. Corgi gas installers are
approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must
be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.
This appliance may be installed next to a wall which is higher than the appliance, with a minimum
distance of 50 mm from the side of the appliance, as shown in the diagram  showing the correct
installation conditions. Any wall cupboards or shelves must be at a distance of at least 750 m above the
work surface.
13.1 Electrical connection
The I.D. plate with techinical data, registration number and brand name is visibily positioned in the
storage compartment.
The plate must not be removed.
If the appliance is connected to the supply by means of a fixed connection, install a multipolar cut-out
device on the line, with contact opening distance equal to or greater than 3 mm, located near the
appliance and in an easily reachable position.
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and socket
must be suitable for the cable employed and conform with the regulations in force. Regardless of the
type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that
the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.
For operation on 220-240V~: use a three-pole H05RR-F cable
having a cross section of 3 x 2.5 mm
2
The cable end to be connected to the appliance must be provided
with ground wire (yellow-green) at least 20 mm longe.
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions.