25
Fault finding
All Raymarine products are designed to provide many years of trouble-free 
operation. We also put them through comprehensive testing and quality 
assurance procedures before shipping.
If a fault occurs with your S1000, use the fault finding tables in this section 
to help identify the problem and provide a solution. If you cannot resolve the 
problem yourself, refer to the product support information. 
            
SYMPTOM
POSSIBLE CAUSE and SOLUTION
Display is blank
No power – press standby to power up the S100 
or change the batteries.
Autopilot not responding.
Drive the boat for 30 seconds at above 2.5kts and 
retry.
Check autopilot connections.
Check GPS is switched on and connected.
Boat turns slowly and takes a 
long time to come onto course
Rudder gain too low. Increase gain setting.
Boat overshoots when turning 
onto a new course
Rudder gain too high. Decrease gain setting.
Position information not 
received
Navigator not transmitting the correct position 
data.
The pilot will not auto advance 
to the next waypoint.
No bearing to waypoint information received from 
the navigator.
Instruments powered from 
SeaTalk will not power up
Check connections
Check fuses
81245_4.book  Page 25  Monday, April 30, 2007  6:03 PM