Configuring via the Web Server
Configuring the System
NetAXS™ Access Control Unit User’s GuideDocument 800-04410, Revision A
 57
2.7.3  Groups Tab
This tab enables you to configure outputs in groups. For example, you might want a group of horns in 
your facility to sound for the same duration or to be enabled or disabled according to the same 
schedule, or time zone. You might want a group of doors to be energized or de-energized during the 
same time zone. A NetAXS™ web server supports up to 64 output groups.
Click 
Groups
 to display the Groups screen:
Figure 2-22:   Configuration > Other I/O & Groups > Groups Tab
The Groups tab enables you to: 
• Associate any of the panel’s eight output relays in one or more groups.
• Configure the following for each group:
– Pulse  Time
– Energized TZ (Time Zone)
– Interlock Disabled TZ (Time Zone)
– Latch