Quantum acl 4 安装指导
Chapter 1 Installation Requirements
Library Specifications
Library Specifications
ACL 4/52 Facilities Planning and Installation Guide
Library Specifications
1
The tables in this section provide the mechanical, power, and
environmental specifications for the Enterprise library. Use these
specifications to help select an appropriate installation site and
environment.
environmental specifications for the Enterprise library. Use these
specifications to help select an appropriate installation site and
environment.
Figure 1 Library Mechanical
Specifications
Specifications
Figure 2 Library Power
Specifications
Specifications
Figure 3 Library Environmental
Specifications
Specifications
Height
44 inches (111.76 cm)
Width
21.5 inches (54.61 cm)
Depth
31.12 inches (79.04 cm)
Weight
361 lbs. (164 kg) with 4 tape drives and 52 DLT cartridges
AC Power Rating
100–120V/200-240V, 4A/2A, 50/60 Hz
AC Voltage Range
90–132 VAC or 180–264 VAC
Frequency Range
47–63 Hz
Temperature:
Storage—Short-Term (<60 Days)
Storage—Long-Term (>60 Days)
Transport
Operating
Storage—Long-Term (>60 Days)
Transport
Operating
-40 to 151
°
F (-40 to 66
°
C)
41 to 122
°
F (5 to 50
°
C)
-40 to 151
°
F (-40 to 66
°
C)
59 to 90
°
F (15 to 32
°
C)
Relative
Humidity:
Humidity:
Non-Operating (Storage)
Non-Operating (Transport)
Operating
Non-Operating (Transport)
Operating
95% (Wet bulb temp = 90
°
F/32
°
C)
95% (Wet bulb temp = 115
°
F/46
°
C)
20–80% (Wet bulb temp =
77
77
°
F/25
°
C)
Altitude:
Short-Term (<60 days in storage)
Long-Term (>60 days in storage)
Operating
Long-Term (>60 days in storage)
Operating
12,000 ft (3,658 km)
12,000 ft (3,658 km)
6,562 ft (2.0 km) @ 76
12,000 ft (3,658 km)
6,562 ft (2.0 km) @ 76
°
F Max.
& 589 mmHg
Heat
Dissipation:
Dissipation:
Operating
880 BTU/hr (220 KCal/hr or 260
watts)
watts)