KitchenAid kudd03dtpa 安装指导

下载
页码 56
6
Electrical Requirements
Contact a qualified electrician.
Ensure that the electrical installation is adequate and in 
conformance with all national and local codes and ordinances.
You must have:
120-volt, 60 Hz, AC-only, 15- or 20- amp fused electrical 
supply.
Copper wire only.
We recommend:
A time-delay fuse or circuit breaker.
A separate circuit.
If direct wiring dishwasher:
Use flexible, armored or nonmetallic sheathed, copper wire 
with grounding wire that meets the wiring requirements for 
your home and local codes and ordinances.
Use strain relief method provided with house wiring junction 
box or install a UL Listed/CSA Approved clamp connector to 
the house wiring junction box. If using conduit, use a 
UL Listed/CSA Approved strain relief.
If connecting dishwasher with a power supply cord:
Use Power Supply Cord Kit (Part Number 4317824) marked 
for use with dishwashers. Kit contents include:
Voltex, Inc., UL Listed 16 gauge 3 wire power supply cord 
with 3 prong grounded plug.
Neer C-500 
⁷⁄₈
" strain relief.
3 wire connectors.
Part No. 302797 grommet.
Follow the kit instructions for installing the power supply cord.
Power supply cord must plug into a mating three prong, 
grounded outlet, located in the cabinet next to the dishwasher 
opening. Outlet must meet all local codes and ordinances.
IMPORTANT: If you plan to install a garbage disposer, an 
additional separate 120-volt, 60 Hz, AC-only, 15 or 20 amp fused 
electrical supply is required.
Drain Requirements
Use the new drain hose supplied with your dishwasher. If this 
is not long enough, use a new drain hose with maximum 
length of 12 ft (3.7 m) that meets all current AHAM/IAPMO test 
standards, is resistant to heat and detergent, and fits the 
1" (2.5 cm) drain connector of the dishwasher.
Connect drain hose to waste tee or disposer inlet above drain 
trap in house plumbing and 20" (50.8 cm) minimum above the 
floor. It is recommended that the drain hose either be looped 
up and securely fastened to the underside of the counter, or 
be connected to an air gap.
Use a drain air gap if the drain hose is connected to house 
plumbing lower than 20" (50.8 cm) above the subfloor or floor.
Use ½" (1.3 cm) minimum I.D. drain line fittings.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
■  
For a grounded, cord-connected dishwasher:
The dishwasher must be grounded. In the event of a 
malfunction or breakdown, grounding will reduce the 
risk of electric shock by providing a path of least 
resistance for electric current. The dishwasher is 
equipped with a cord having an equipment-grounding 
conductor and a grounding plug. The plug must be 
plugged into an appropriate outlet that is installed and 
grounded in accordance with all local codes and 
ordinances.
WARNING: 
Improper connection of the 
equipment-grounding conductor can result in a risk of 
electric shock. Check with a qualified electrician or 
service representative if you are in doubt whether the 
dishwasher is properly grounded. Do not modify the 
plug provided with the dishwasher; if it will not fit the 
outlet, have a proper outlet installed by a qualified 
electrician.
■  
For a permanently connected dishwasher:
The dishwasher must be connected to a grounded 
metal, permanent wiring system, or an equipment-
grounding conductor must be run with the circuit 
conductors and connected to the equipment-
grounding terminal or lead on the dishwasher.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS