The bar at the top of the graphic indicates the part examined. 
To view the bits per tone in a tabular format press the 
 key and go on page 3 of 6. 
Now each tone is listed along with the number of bits assigned. 
6.2.2. G.826 
Page 4 shows the values detected according to G.826 to monitor the in-service line 
quality parameters. 
 
Goes to page 4. 
This standard allows to check the access quality without performing specific off-
service tests. 
G.826 measures errors and alarms in the flow through the analysis of the 
synchronism blocks (CRC) intrinsically contained in the frame. 
The results allow to measure the unavailability flow time (UAS), number of errored 
seconds (ES), number of severely errored seconds (SES) and errored blocks 
(BBER) both in uni-directional mode for each direction (Downstream, Upstream) and 
in bi-directional mode, by considering the flow as a single communication channel. 