Frigidaire fgef304dk 用户手册

下载
页码 12
2
30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
2.  Install Anti-Tip Bracket 
(See instructions on 
page 4.)
The user is responsible for connecting the power supply cord 
to the connection block located behind the back panel access 
cover.
This appliance may be connected by means of permanent 
"hard wiring"; flexible armored or nonmetallic shielded copper 
cable (when local code allow it) or by means of a power supply 
cord kit.
NOTE: Electric Slide-in Range is shipped from factory with 1 
1/8" (2.9 cm) dia. hole as shown on figure 4. If a larger hole is 
required, punch out the knockout.
 Risk of fire or electrical shock exists if 
an incorrect size range cord kit is used, the Installation 
Instructions are not followed, or the strain relief bracket 
is discarded.
For mobile homes, new installations or recreational vehicles, 
use only a power supply kit designed for a range at 125V/250V 
50A recommended (minimum 40A). Cord must have either 
3 (when local code permits grounding through neutral) or 4 
conductors. Terminal on end of wires must be either closed 
loop or open spade lug with upturned ends. Cord must have 
strain-relief clamp. If a 50A circuit is used, a 50A power cord 
must be used.
 Do not loosen the nuts which secure the 
factory-installed range wiring to terminal block while 
connecting range. Electrical failure or loss of electrical 
connection may occur.
4.  Electrical Connection Requirements
This appliance must be properly installed and 
grounded by a qualified technician in accordance with 
the National Electrical Code ANSI/NFPA No. 70--latest 
edition--and local electrical code requirements.
This appliance may be connected by means of 
permanent "Hard Wiring" or "Power Supply Cord Kit."
When hard wiring, do not leave excess wire in range 
compartment. Excess wire in the range compartment 
may not allow the access cover to be replaced 
properly, and could create a potential electrical hazard 
if wires become pinched. When using flexible conduit 
or range cable, use flex connector or range cable strain 
relief.
NOTE: Only use copper wire in connection to terminal 
block.
4.1 Models Requiring Power Supply Cord Kit
Figure 2 – 3-Wire Cord Kit
Figure 1
3.  Serial Plate 
Information
 
The serial plate is 
located as shown. 
See the serial plate 
for the following 
information:
 
A.  Model, lot and 
serial number of 
range.
 
B.  Kilowatt rating 
(power requirements).
 
C.  Voltage ratings.
Electrical Shock Hazard
•  Electrical ground is required on this appliance.
•  Do not connect to the electrical supply until
appliance is permanently grounded.
•  Disconnect power to the circuit breaker or fuse box
before making the electrical connection.
•  This appliance must be connected to a grounded,
metallic, permanent wiring system, or a grounding 
connector should be connected to the grounding 
terminal or wire lead on the appliance.
Failure to do any of the above could result in a fire, 
personal injury or electrical shock.
 This appliance is manufactured with 
the frame grounded by connection of a grounding 
strap between the neutral power supply terminal 
and the frame. If used in USA, in a new branch circuit 
installation (1996 NEC), mobile home or recreational 
vehicule, where local code do not permit grounding 
through neutral (white) wire or in Canada; remove the 
grounding strap from the frame and cut the other end, 
near the neutral terminal. Connect the appliance in 
usual manner.