Frigidaire fgef304dk 用户手册

下载
页码 12
3
30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the frame 
grounding conductor to the neutral wire of the copper power 
supply cord (see Figure 4):
1.  Remove the screws from the access plate at the lower right 
end of the rear cover to expose range terminal connection 
block.
2.  Remove the grounding strap from the terminal block and 
from the appliance frame. 
3.  Using the nuts supplied with the literature package, 
connect the ground wire (green) of the copper power 
supply cord to the frame of the appliance with the ground 
screw, using the hole in the frame where the ground strap 
was removed (see Figure 4).
4.  Connect the neutral of the copper power supply cord to 
the center silver-colored terminal of the terminal block, 
and connect the other wires to the outer terminals. Match 
wires and terminals by color (red wires connected to the 
right terminal, black wires connected to the left terminal).
5.  Replace the terminal cover and replace the screws.
Terminal Block
Silver Colored Terminal 
Red
Wire
Neutral 
(White Wire)
Ground (Bare 
Copper Wire)
To 240 V Receptacle
A User Supplied 
Strain-relief Must 
Be Installed at This 
Location
Black Wire
1 1/8" (2.9cm) 
Dia. Direct 
Connection 
Hole. Punch 
Out Knockout 
for 1 3/8" 
(3.5cm) Dia. 
Cord Kit Hole.
NOTE: Be sure to remove the 
supplied grounding strap.
Figure 4
Three Conductor Wire Connection to Range
If local codes permit connection of the frame grounding 
conductor to the neutral wire of the copper power supply cord 
(see Figure 3):
1.  Remove the screws from the access plate at the lower right 
end of the rear cover to expose range terminal connection 
block.
2.  Using the nuts supplied in the literature package, connect 
the neutral of the copper power supply cord to the center 
silver-colored terminal of the terminal block, and connect 
the other wires to the outer terminals. Match wires and 
terminals by color (red wires connected to the right 
terminal, black wires connected to the left terminal) (see 
figure 3).
3.  Replace the terminal cover and replace the screws.
Figure 3
Silver Colored Terminal
1 1/8" (2.9 cm) Dia. 
Direct Connection 
Hole. Punch Out 
Knockout for 1 3/8" 
(3.5 cm) Dia. Cord 
Kit Hole.
To 240 V 
Receptacle
A User Supplied 
Strain-relief Must 
Be Installed at This 
Location.
Black 
Wire
Terminal
Block
Cord 
Mounting 
Plate
Neutral 
(White Wire)
Grounding
Strap
Red Wire