Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box, and then install a 
UL listed or CSA approved
 ¹⁄₂" (12.7 mm) strain relief.
4. Run home power supply cable through strain relief and into 
the terminal box.
5. Use UL listed wire connectors and connect black wires (C) 
together.
6. Use UL listed wire connectors and connect white wires (E) 
together.
7. Connect green (or bare) ground wire from home power supply 
to yellow-green ground wire (F) in terminal box using UL listed 
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions 
supplied with the power cord kit. See the “Assistance or Service” 
section for information on ordering.
NOTE: Use only with range hood cord connection kits that have 
been investigated and found acceptable for use with this model 
range hood.
Install Duct Covers
NOTE: Remove the film from the duct covers.
1. Assemble the upper duct covers together, and then install the 
duct covers around the support frame. The larger hole in the 
flanges of the upper duct cover must be outside the smaller 
hole in the mating flange of the other upper duct cover.
2. Secure the upper duct covers together with two 3.5 x 6.5 mm 
screws at the top and two 2.9 x 3 mm screws at the bottom. 
Install 1 screw on each side at the top and bottom of the 
assembled duct covers.
A. Knockout
B. Terminal box
C. Terminal box cover
A. Home power supply cable
B. UL listed or CSA approved 
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-
green ground wires
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
C
B
A
B
C
D
E
F
A. 3.5 x 6.5 mm screws (2)
B. Assembly holes (larger hole outside of 
smaller hole on both sides)
C. 2.9 x 3 mm screws (2)
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A
A
B
C
C