KitchenAid 30'' Wall-Mount 600 CFM Canopy Hood, Commercial-Style 安装指南

下载
页码 36
10
4. Push the right end of the motor mounting plate up and snap it 
into the spring tab.
NOTE: The spring tab should be outside the slot in the 
mounting plate.
5. Align mounting holes in motor mounting plate with motor 
mounting clip nuts and install 6 x 16 mm screws and 6.4 mm 
lock washers (quantity 2 for single motor; quantity 5 for dual 
motor).
6. Attach power supply connector from the range hood to the 
connector on the blower motor assembly wiring box.
7. Go to the “Make Electric Power Supply Connection to Range 
Hood” section.
Install Range Hood In-Line (External Type) 
Blower Motor
NOTE: Your range hood requires you to purchase either an 
internal type or an in-line (external type) blower motor system. 
See “Blower Motor System” in the “Accessories” section.
Prepare for Mounting the In-Line Blower System
The in-line blower system must be fastened to a secure structure 
of the roof, ceiling, wall, floor, or new or existing frame 
construction. The 4 holes on either the inlet (bottom) side or the 
outlet (top) side of the blower must be used to mount the in-line 
blower system to the structure.
NOTE: The mounting hole locations must span the studs. 
Additional stud framing may be required. Plywood may be used 
to span open areas between ceiling joists or roof rafters to aid 
installation. This structure must be strong enough to support the 
weight of the in-line blower system (50 lb [22.6 kg] min).
Prepare the In-line Blower System
1. Using 2 or more people, move the in-line blower motor 
system to the mounting location.
2. Remove the 10 screws from the front cover of the in-line 
blower motor housing and set them aside.
3. Remove the front cover of the in-line blower motor housing 
and set it aside.
NOTE: To make the blower motor housing easier to mount, 
the blower motor assembly can be removed. If you do not 
want to remove the blower motor assembly, proceed to 
“Install In-line Blower System” in this section.
4. Disconnect the motor electrical plug from the blower motor 
assembly.
5. Remove the screws that secure the blower motor assembly 
to the in-line blower housing and set them aside.
6. Pull the spring clip to release the blower motor assembly. 
Remove the blower motor assembly from the housing and 
place it on a covered surface.
A. Motor mounting plate
B. Spring clip
A. Screw with lock washer
B. Mounting hole in motor mounting plate
C. Clip nut (6 mm)
A. Wiring box connector
B. Power supply connector from range hood
A
B
A
B
C
B
A
A. Front cover
B. Blower mounting screws
C. Spring clip
D. Motor electrical plug
WARNING
Excessive Weight Hazard
Use two or more people to move and install in-line 
blower motor system.
Failure to do so can result in back or other injury.
A
B C
D