Make Electrical Connections for In-Line Blower Motor System
Electrical Connection Inside In-line Blower System
1. Disconnect power.
2. Connect the wires from the wiring conduit to the wires from 
the motor electrical plug cable inside the in-line blower 
housing terminal box.
3. Use UL listed wire connectors and connect the black wires 
(C) together.
4. Use UL listed wire connectors and connect the white wires 
(D) together.
5. Use UL listed wire connectors and connect the red wires (E) 
together.
6. Use UL listed wire connectors and connect the blue wires (F) 
together.
7. Use UL listed wire connectors and connect the gray wires (G) 
together.
8. Connect the green (or yellow/green) ground wire to the 
green/yellow ground wire (H) in the terminal box using UL 
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and 
secure it with 10 mounting screws.
Electrical Connection Inside Range Hood Between In-line 
Blower System and Range Hood
1. With the range hood mounted (see the “Install Range Hood” 
section), locate the wiring cable connector inside the range 
hood.
2. Connect the 6-wire connector assembly supplied with the 
in-line blower motor system to the mating cable connector 
from the range hood. 
3. Locate the terminal box inside the range hood and install a 
¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see 
“Complete Preparation” in the “Prepare Location” section). 
4. Run the wire ends from the 6-wire connector assembly 
through the 
¹⁄₂" (1.3 cm) strain relief, leaving enough wire 
length to make the wiring connections. Tighten the strain 
relief screws.
5. Connect the wires from the 6-wire connector assembly to the 
wires from the wiring conduit inside the range hood terminal 
box. 
A. UL listed or CSA approved 
¹⁄₂
" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/green) 
and green/yellow wires
I. Motor electrical plug cable
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
G
H
I
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.