The grounded 3 prong outlet is to be located inside the 
cabinet above the range hood at a maximum distance of 
33
7
/
16
" (85 cm) from where the power cord exits the hood. 
INSTALLATION INSTRUCTIONS
Prepare Location
NOTE: For vented installations, it is recommended that 
the vent system be installed before hood is installed.
Before making cutouts, make sure there is proper 
clearance within the ceiling or wall for exhaust vent.
1.  For vented installations, determine which venting 
method to use: roof or wall.
2.  Select a flat surface for assembling the range hood. 
Place covering over that surface.
3.  Using 2 or more people, lift the range hood and set 
it upside down onto covered surface.
4.  If cabinet has recessed bottom, add wood filler strips 
on each side. Install screws to attach filler strips in 
locations shown.
Determine Wiring Hole Location
Cut only one 1
1
/
4
" (3.2 cm) diameter wiring access hole. 
See Step 2 for wiring hole location instructions.
1.  Determine and clearly mark a vertical centerline on the 
wall and cabinet in the area the vent opening will be made.
2.  To wire through top:
Mark a line distance “A” from the left of the centerline 
on the underside of the cabinet. Mark the point on this 
line that is 2" (5.1 cm) from back wall. Drill a 1
1
/
4
" (3.2 cm) 
diameter hole through the cabinet at this point.
33⁷⁄₁₆" (85 cm)
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected range hood: 
This range hood must be grounded. In the event of an 
electrical short circuit, grounding reduces the risk of electric 
shock by providing an escape wire for the electric current. 
This range hood is equipped with a cord having a grounding 
wire with a grounding plug. The plug must be plugged into 
an outlet that is properly installed and grounded.
WARNING: 
Improper grounding can result in a risk of 
electric shock.
Consult a qualified electrician if the grounding instructions 
are not completely understood, or if doubt exists as to 
whether the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too 
short, have a qualified electrician install an outlet near the 
range hood.
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
range hood.
Failure to do so can result in back or other injury.
Cabinet
bottom
Wall
3" (7.6 cm)
Wood filler strips
(recessed cabinet
bottoms only)
3" (7.6 cm)
A
A. Centerline
Centerline
2" (5.1 cm)
from wall,
not cabinet
frame
A
A.  12" (30.5 cm)