ASM-60 Installation and Operation Manual 
Chapter 2  Installation and Setup 
 
Installation and Setup 
2-3 
Opening the ASM-60 Case 
 
To open the ASM-60 case: 
1.  Disconnect the power cord from the power source. 
2.  Slide the blue side panel forward to detach it from the case. 
3.  Unscrew the two screws located on the bottom panel at the rear end of the 
unit.  
4.  Separate the two halves of the ASM-60 case by lifting the top cover at the end 
of the unit and sliding it forward. 
Closing the ASM-60 Case 
After completing the internal settings, close the unit case. 
 
To close the ASM-60 case: 
1.  Position the lower half of the ASM-60 case on the flat surface. 
2.  Return the top cover. Make sure that the front board CONTROL DCE 
connector fits the front panel opening correctly, and the top cover guides enter 
the corresponding recesses at the end of the unit. 
3.  Secure the two screws located at the end of the unit. 
4.  Fit the inside tabs of the blue side panel into the unit case grooves, and slide 
the side panel until it snaps into place. 
Connecting the Interfaces  
 shows the rear panel of a typical ASM-60 unit with HSSI interface.  
A-1  2
4  5-B
: FOR CONTINUED
TYPE AND RATING OF FUSE.
FIRE, REPLACE ONLY WITH SAME
PROTECTION AGAINST RISK OF
CAUTION
LINE
HSSI
 
Figure 2-1  Rear Panel of ASM-60 with HSSI Interface 
Connecting the Line  
The ASM-60 line interface terminates in an 8-pin RJ-45 connector (see 
 
To connect the RJ-45 connector: 
•  Connect the line cable to the RJ-45 connector designated LINE. 
Table 2-1  Line Connector Pinout 
Pin Function 
1, 2 
Line A 
4, 5 
Line B 
11, 12 
Chassis