Fujitsu C120-E361-04EN 用户手册

下载
页码 36
1-6
C120-E361-04EN
CHAPTER 1  RCI Build Procedure 
1.3.2
New setup of two RCI Hosts
Figure 1.6  New setup of two RCI Hosts
1
Log in to the XSCF Shell.
2
On main unit A, execute the setrci -c stat command to display the RCI status.
3
Verify that the RCI address is 000f7fff.
Remarks:  000f7fff is the default value of the RCI address.  If the default value is not 
set, execute the setrci -c init command to initialize the value.
If the system is powered off, you can use the setrci -c init command.
4
In a similar manner, display the RCI status of main unit B to verify that the RCI 
address is 000f7fff.  
5
Connect the main unit and I/O units with RCI cables (see 
Connect an RCI branching connector to each of the RCI ports, and connect them with 
RCI cables by using a daisy-chain connection.
Connect an RCI terminating resistor to the branching connector at either end of the 
6
Turn on the AC input to all the RCI device which are in the RCI connection.
XSCF> setrci -c stat
HOST
 address 000f7fff
 Inactive
The command completed successfully
XSCF> setrci -c init
The command completed successfully
RCI I/O unit
RCI I/O unit
RCI 
Host A
RCI 
Host B