Redline Communications Inc. AN100UXA 用户手册

下载
页码 136
 
 
 
User
 
 
AN-100U/UX Base Station
 
Manual
 
 
 
70-00058-01-04 
Proprietary Redline Communications © 2010  
Page 27 of 136 
April 19, 2010 
 
 
 
Figure 8: System - AN-100UX Front Panel 
3.1.1  Mounting 
The indoor equipment can be freestanding on a flat surface or in a 19-inch rack. 
3.1.2  Power Supply 
The  AN-100U  and  AN-100UX  (high  power)  equipment  have  different  power  supply 
features.  Read  the  following  section  carefully  to  determine  the  correct  power 
requirements  and  options.  All  models  feature  double  pole/neutral  fusing.  Refer  to  the 
Installation Guidelines manual for additional information about DC power wiring. 
Warning to service personnel:
 
Caution for all AC and DC models 
– Double Pole/Neutral fusing.
 
 
AN-100U 
Power supply options include single or dual AC or DC supplies, or a combination of AC 
and DC power supplies. Cables are included with both AC and DC power supplies. 
Table 7 - IDU Installation - RedMAX AN-100U Power Specifications 
 
Voltage range 
[V] 
Tolerance 
[%] 
Power 
consumption 
max. [W] 
Max. 
Current 
[A] 
Inrush 
current 
1
 
[A] 
AC Input 
2
 
100-240 VAC 
10% 
75 
35 
DC Input 
2
 
24-60 VDC 
20% 
75 
40 
1. Typical Inrush current is less then 500 us. DC: measured, AC: P/S manufacturers data. 