Honeywell BOTAC01 用户手册
Honeywell IdentIPoint Intelligent Smartcard Readers
Fig.24. Reader and magnetic
lock
lock
Power – Min. 18 AWG
Power Gnd – Min. 18 AWG
LEGEND
Ethernet
S1
1
2
3
4
OFF ON
Magnetic Lock
IdentIPoint Reader
1
Power‐OUT
SAI‐1‐GND
9
2
Power‐GND
SAI‐1
8
3
RS485‐A
SAI‐0‐GND
7
4
RS485‐B
SAI‐0
6
5
RS485‐GND
Relay‐NO
5
6
DO
Relay‐NC
4
7
DOGnd
Relay‐C
3
8
SAI‐2
Power‐GND
2
9
SAI‐2‐GND
Power‐IN
1
Frame‐GND
J10
J9
PIN
PIN
DC – Power
12VDC/24VDC
10
S1
Fig.25. IOM and magnetic
lock
lock
Power – Min. 18 AWG
Power Gnd – Min. 18 AWG
LEGEND
RL1‐C
N.O
GND
N.C
12V
RLO‐C
GND
N.O
SAO
N.C
GND
485‐A
SAI‐3
485‐B
GND
485‐
GND
GND
SAI‐2
ILK‐1
GND
GND
SAI‐1
ILK‐0
GND
GND
SAI‐0
D1‐0
GND
GND
DI‐1
DO‐0
GND
GND
DI‐0
DC – Power
12VDC/24VDC
FGND
IO module
Magnetic Lock
95-7771