Honeywell BOTAC01 用户手册
Honeywell IdentIPoint Intelligent Smartcard Readers
95-7771
27
SAI-n
SAI-n GND
1KΩ
2K
Ω
Ω
Sensor
Switch
Switch
SAI-n
SAI-n GND
1KΩ
2K
Ω
Ω
Sensor
Switch
Switch
Fig.26. Supervisory Analog Inputs
Note: Door sense is considered open when sensor switch is open
11
22
33
EACH DOOR STRIKE REQUIRES A
14507020‐001 DIODE SUPPRESSION
NETWORK. DOOR STRIKE MAY DRAW A
NETWORK. DOOR STRIKE MAY DRAW A
MAXIMUM CURRENT OF 2A; REGULATED 12/ 24
VDC. DOOR STRIKE MUST BE UL LISTED.
VDC. DOOR STRIKE MUST BE UL LISTED.
EXIT SWITCH: WIRING MUST BE
COMPLETED WITHIN THE PROTECTED
AREA OR NOT READILY ACCESSIBLE OUTSIDE THE
PROTECTED AREA.
PROTECTED AREA.
44
ALL WIRING MUST CONFORM TO
APPLICABLE LOCAL CODES,
ORDINANCES, AND REGULATIONS
DOOR CONTACTS MUST BE UL LISTED.
MAXIMUM WIRE LENGTH 500 FT (152M).
WIRE TYPE 18 AWG (0.8 SQ MM), 50 OHM 60
mA MAXIMUM.
mA MAXIMUM.
55
DO NOT ROUTE COMMUNICATION
WIRES WITH POWER OR LOCKING
DEVICES.
NOTE: FOR COMMUNICATION CIRCUITS AND
OTHER APPLICABLE WIRING CIRCUITS WHERE
WIRING ENTERS AND EXITS THE BUILDING,
REFER TO LIGHTNING PROTECTOR TABLE FOR
APPROPRIATE LIGHTNING PROTECTOR USAGE.
OTHER APPLICABLE WIRING CIRCUITS WHERE
WIRING ENTERS AND EXITS THE BUILDING,
REFER TO LIGHTNING PROTECTOR TABLE FOR
APPROPRIATE LIGHTNING PROTECTOR USAGE.