Honeywell BOTAC01 用户手册

下载
页码 32
Honeywell IdentIPoint Intelligent Smartcard Readers 
 
95-7771 
27 
 
 
SAI-n
SAI-n GND
1KΩ
2K
Ω
Sensor 
Switch
SAI-n
SAI-n GND
1KΩ
2K
Ω
Sensor 
Switch
Fig.26. Supervisory Analog Inputs
 
 
 
 
 
 
 
Note: Door sense is considered open when sensor switch is open 
 
 
11
22
33
EACH DOOR STRIKE REQUIRES A 
14507020‐001 DIODE SUPPRESSION 
NETWORK. DOOR STRIKE MAY DRAW A 
MAXIMUM CURRENT OF 2A; REGULATED 12/ 24 
VDC. DOOR STRIKE MUST BE UL LISTED. 
 EXIT SWITCH: WIRING MUST BE 
COMPLETED WITHIN THE PROTECTED 
AREA OR NOT READILY ACCESSIBLE OUTSIDE THE 
PROTECTED AREA.  
 
 
44
ALL WIRING MUST CONFORM TO 
APPLICABLE LOCAL CODES, 
ORDINANCES, AND REGULATIONS 
DOOR CONTACTS MUST BE UL LISTED. 
MAXIMUM WIRE LENGTH 500 FT (152M). 
WIRE TYPE 18 AWG (0.8 SQ MM), 50 OHM 60 
mA MAXIMUM. 
 
55
DO NOT ROUTE COMMUNICATION 
WIRES WITH POWER OR LOCKING 
DEVICES. 
 
 
 
NOTE: FOR COMMUNICATION CIRCUITS AND 
OTHER APPLICABLE WIRING CIRCUITS WHERE 
WIRING ENTERS AND EXITS THE BUILDING, 
REFER TO LIGHTNING PROTECTOR TABLE FOR 
APPROPRIATE LIGHTNING PROTECTOR USAGE.