  Chapter 7 Application Programming 
DMC-2X00  
Program Format 
A DMC program consists of DMC-2x00 instructions combined to solve a machine control application.  
Action instructions, such as starting and stopping motion, are combined with Program Flow 
instructions to form the complete program.  Program Flow instructions evaluate real-time conditions, 
such as elapsed time or motion complete, and alter program flow accordingly. 
Each DMC-2x00 instruction in a program must be separated by a delimiter.  Valid delimiters are the 
semicolon (;) or carriage return.  The semicolon is used to separate multiple instructions on a single 
program line where the maximum number of instructions on a line is limited by 80 characters.  A 
carriage return enters the final command on a program line. 
Using Labels in Programs 
All DMC-2x00 programs must begin with a label and end with an End (EN) statement.  Labels start 
with the pound (#) sign followed by a maximum of seven characters.  The first character must be a 
letter; after that, numbers are permitted.  Spaces are not permitted. 
The maximum number of labels which may be defined is 510, for firmware 1.0c and higher. 
Valid labels 
 #BEGIN 
 #SQUARE 
 #X1 
 #BEGIN1 
Invalid labels 
 #1Square 
 #123 
Example 
 
Instruction Interpretation 
#START 
Beginning of the Program 
PR 10000,20000 
Specify relative distances on A and B axes 
BG AB 
Begin Motion 
AM 
Wait for motion complete 
WT 2000 
Wait 2 sec 
JP #START 
Jump to label START 
EN 
End of Program 
The above program moves A and B 10000 and 20000 units.  After the motion is complete, the motors 
rest for 2 seconds.  The cycle repeats indefinitely until the stop command is issued. 
Special Labels 
The DMC-2x00 has some special labels, which are used to define input interrupt subroutines, limit 
switch subroutines, error handling subroutines, and command error subroutines.  See section on Auto-
Start Routine 
The DMC-2x00 has a special label for automatic program execution.  A program which has been saved 
into the controller’s non-volatile memory can be automatically executed upon power up or reset by