Cisco Systems WS-X6608-T1 用户手册

下载
页码 128
4-2
Ci sco Catalyst  4900M Swit ch I nst allati on Guide
78-18350-02
Chapter 4      Troubleshootin g t he Inst allat ion
  Problem Solving to the System Component Level
Problem Solving to the System Component Level
The key to success when trou bles hooting  the system is to isolate the pro blem to a sp ecific system 
compo nen t. The first step is  to compare what the s ystem is doing  to what it shou ld b e  doing . Because a 
startup problem can usually be attributed to a single co mponent, it is  mo re efficient to  is olate the pro blem 
to  a subsystem rather than trou blesh oot each s eparate comp onent in  the system.
The switch consists of the following sub systems:
  •
Power supply —In clud es th e p ower sup ply and power sup ply cooling . (See th
.)
  •
Fan assembly system—Th e chas sis fan  assembly shou ld o perate wh enever system p ower is on. 
Usually, it continu es to operate even when the env iron mental monitor s huts down the system 
b ecau se of an overtemperature or overvoltag e condition. (It will shut down  for a power supp ly 
sh utdown .) You sh ould be able to h ear the fan ass embly  to determine whether or not it is operating. 
If the FAN LED is orange an d y ou determine that the fan assembly is n ot operating, y ou should  
immediately  contact a custo mer s ervice representative. There are no  ins tallation ad justments th at 
y ou can mak e if the fan assembly does not fu nctio n prop erly at the in itial startup .
Identifying Startup Problems
When you connect the power cord s to  th e Catalyst 490 0M s witch, follow these steps:
Step 1
Flip the p ower switches to th e on pos ition (AC powered systems only).
Step 2
Verify  that power is available to the p ower supp lied from the s ite AC o r DC source. Flip breakers and 
fuses if necessary.
Step 3
Listen  for the system fan  assembly. If you do not immediately hear the sys tem fan as sembly  begin to 
o perate, see 
Step 4
If you  d etermin e that th e power su pplies are fu nctio ning normally  and that th e fan assemb ly is faulty, 
contact a customer s ervice rep resen tative. If th e sys tem fan assembly do es no t fun ction  prop erly at initial 
startup, th ere are no installation adjustments that yo u can make.
LED Readings
LEDs  indicate all system states  in the startu p sequence. By check ing the LEDs, yo u can  determine  when 
and wh ere the system failed in the startup seq uen ce. To check the LEDs, follow th ese step s:
Step 1
Comp are the LED states to  tho se listed in 
.