Cisco Systems WS-X6608-T1 用户手册

下载
页码 128
3-22
Ci sco Catalyst  4900M Swit ch I nst allati on Guide
78-18350-02
Chapte r 3      Inst allin g t he Swi tch
  Removi ng and Replacing the Fan Assembly
Installing the Fan Assembly
To install the new fan assembly, perform the fo llowing steps:
Step 1
Hold the fan  assembly with the captive screws on the left. 
Step 2
Place the fan  assemb ly  into  the  fan assembly bay  so it rests on  the  ch assis, and  then  lift  the  fan assembly 
u p s lig htly,  alig ning  the to p and  bo ttom g uides.
Step 3
Slide the fan assemb ly into the chassis until the two  captive installation  screws make contact with th e 
chassis.
Step 4
Using a screwd river, tighten the two captive installation screws b y tu rning  th em clo ck wise. 
Verifying the Installation
Note
To ch eck the op eratio n of the fans, yo u n eed to power up  the ch assis.
To verify  th at the n ew fan assemb ly was  ins talled correctly, perform the following step s:
Step 1
Listen  for the fans; you shou ld immediately h ear them operating. If y ou do not hear th em, ens ure that 
th e fan  as sembly  is inserted  comp letely in  the  chassis and  that the faceplate is flu sh with the switch b ack 
p anel.
Step 2
The fan tray LED shou ld b e lit green.
Step 3
If after several attemp ts  the fans do not operate, or if you experience tro uble with the installation (for 
in stance, if the captive in stallation screws do not align with the chassis holes), co ntact the Cisco TAC 