AeroComm CL4490-1000 用户手册

下载
页码 22
CL4490 User’s Manual
 
 
1.3 CL4490 
Interface 
The CL4490 supports RS-232/RS-485 (2-wire Half Duplex) protocols.  By definition, RS-485 
protocol can tolerate high noise and push signals over long cable lengths.  When using cables, 
RS-485 will communicate as far as 4000feet (1200m) and offer multi-drop capability where up to 
32 nodes may be connected.  RS-232 cables are suitable for distances less than 100 feet 
(30.5m).  AeroComm wireless solutions are not subject to the cabling restrictions for distance, but 
either interface (RS-232 or RS-485) is available when ordering the CL4490s.  
 
Figure 1- RS-232/RS-485 CL4490 Front View 
 
 
RPSMA Antenna Connector
Status LEDs
Pwr
Link
Rx
Tx
 
 
 
 
CL4490 Status LEDs 
LED 
Color 
Description 
Pwr Green 
On indicates that the unit is powered up. 
Link Red 
On indicates the Client unit(s) and Server unit are in range of one 
another.  Link LED remains activated on Server units.  Client units 
activate the Link LED when in range of the Server unit. 
Rx Green 
When flashing, LED indicates CL4490 unit is receiving data. 
Tx Red 
When and flashing, LED indicates CL4490 unit is sending data. 
 
 
 
 
 
10/3/2005  