 57 
Setting up Sinusoidal Encoders 
The  Sinusoidal  position  feedback  is  set  up  through  the  Encoder  Conversion  Table  (ECT)  as  a  high 
resolution interpolation entry. 
 
Encoder Conversion Table Setup Example, Channel 1 
 
1.  Conversion Type: High res. interpolator, PMAC2 Style 
2.  Enter Source Address (see table below)  
3.  Enter A/D Converter Address (see table below) 
4.  A/D Bias: always zero 
 
Channel # 
Source 
Address 
A/D converter 
Address 
  Channel # 
Source 
Address 
A/D converter 
Address 
$78000 
$78B00 
 
$78100 
$78B08 
$78008 
$78B02 
 
$78108 
$78B0A 
$78010 
$78B04 
 
$78110 
$78B0C 
$78018 
$78B06 
 
$78118 
$78B0E 
 
 
Note 
Results  are  found  in  the  processed  data  address,  which  the  position 