Delta Tau GEO BRICK LV User Manual

Page of 271
Geo Brick LV User Manual
 
PinOuts and Software Setup 
 57 
Setting up Sinusoidal Encoders 
The  Sinusoidal  position  feedback  is  set  up  through  the  Encoder  Conversion  Table  (ECT)  as  a  high 
resolution interpolation entry. 
 
Encoder Conversion Table Setup Example, Channel 1 
 
1.  Conversion Type: High res. interpolator, PMAC2 Style 
2.  Enter Source Address (see table below)  
3.  Enter A/D Converter Address (see table below) 
4.  A/D Bias: always zero 
 
Channel # 
Source 
Address 
A/D converter 
Address 
  Channel # 
Source 
Address 
A/D converter 
Address 
$78000 
$78B00 
 
$78100 
$78B08 
$78008 
$78B02 
 
$78108 
$78B0A 
$78010 
$78B04 
 
$78110 
$78B0C 
$78018 
$78B06 
 
$78118 
$78B0E 
 
 
Note 
Results  are  found  in  the  processed  data  address,  which  the  position 
and velocity feedback pointers (Ixx03, Ixx04) are usually assigned to.