ICP-CC404 | Installation Guide | 6.0   System Functions 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 
31
 
To enter Satellite Siren Service Mode: 
Enter the Installer Code and press [5][AWAY]. 
Three beeps sound. 
6.1.6 
Turning Telephone Monitor Mode On and 
Off 
Telephone Monitor Mode allows you to use the 
remote codepad for visual representation of data 
transmissions between the control panel and the base 
station receiver. The dialing sequence is also shown in 
this mode. 
The codepad beeps once every 2 sec when 
Telephone Monitor Mode is active, whether the 
system is in Installer’s Programming Mode or normal 
operating mode. The first five indicators show the 
progressive steps during a transmission to the base 
station receiver. 
 
Table 24: 
Telephone Monitor Mode Indications 
 
Zone LED 
Dialing Event 
Telephone line seized 
Dialing phone number 
Handshake received 
4 Data 
being 
transmitted 
Kiss-off received 
None 
Telephone line released 
 
To turn Telephone Monitor Mode on: 
Enter the Installer Code and press [6][AWAY]. 
Three beeps sound. 
To turn Telephone Monitor Mode off: 
Enter the Installer Code and press [6][AWAY]. 
Two beeps sound. 
 
 
You must exit from Telephone Monitor 
Mode to resume normal operations. 
6.1.7 
Walk Test Mode 
Walk Test Mode allows you to test detection devices 
to ensure they are functioning correctly. Before 
activating Walk Test Mode, isolate any zones that are 
not required for testing. Refer to Section 4.11 Isolating 
Zones
 on page 21 for more information.  
To enter Walk Test Mode: 
1.  Enter the Installer Code and press [7][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. The codepad beeps once per sec 
when Walk Test Mode is active. 
2.  Unseal and seal the zones to be tested.  
The codepad sounds one long beep and the horn 
speaker sounds one short beep each time a zone 
is sealed or unsealed. 
3.  Press [AWAY] to exit from this function.  
Two beeps sound and the STAY and AWAY 
indicators turn off. The system returns to the 
disarmed state. 
6.1.8 
Event Memory Recall Mode 
This function allows you to play back the last 40 
system events that occurred. Event Memory Recall 
Mode reports all alarms and each arming or 
disarming of the system and helps with 
troubleshooting system faults. The events are shown 
using the codepad indicators. 
To enter Event Memory Recall Mode: 
Enter the Installer Code and press [8][AWAY]. 
Three beeps sound. The events are played back by 
the codepad indicators in reverse chronological order. 
Example 
If the events occurred in the following order: 
1.  System armed in AWAY Mode 
2.  Alarm in Zone 3 
3.  Alarm in Zone 4 
4.  System disarmed 
The alarm memory plays back in this order: 
1.  All indicators off except MAINS (System 
disarmed) 
2.  Zone 4 and AWAY indicators light (Alarm in 
Zone 4) 
3.  Zone 3 and AWAY indicators light (Alarm in 
Zone 3) 
4.  AWAY indicator lights (System armed in AWAY 
Mode) 
Each event is indicated by a beep and a lit indicator. 
Resetting a disarmed 24-Hour Alarm is indicated by a 
beep only. 
After the last event, three beeps sound to indicate the 
end of playback. You can stop the replay at any time 
by pressing [AWAY]. 
 
If the system is armed in STAY Mode 1 or 
STAY Mode 2, the STAY indicator shows 
the event memory playback. There is no 
differentiation between STAY Mode 1 and 
STAY Mode 2. 
If power is removed from the control 
panel, the memory of all events is saved. 
 
6.2 Master 
Code 
Functions 
Master Code Functions allow users with the 
appropriate priority level to perform certain 
supervisory level functions. You can use these 
functions only when the system is disarmed.