Bosch Appliances Home Security System ICP-CC404 用户手册

下载
页码 98
ICP-CC404 | Installation Guide | 6.0  
System Functions 
 
 
30 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
To disable the Telco disarming sequence: 
Enter the Installer Code and press [3][AWAY][2] 
[AWAY][STAY][4][AWAY]. 
To program the Telco arming sequence – easy 
call forward (immediate on): 
1.  Enter the Installer Code and press [3][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Press [1][AWAY] button to change the Telco 
arming sequence. Three beeps sound.   
If a call forwarding sequence is already 
programmed, the sequence appears one digit at a 
time using the remote codepad indicators. Refer 
to Table 23 on page 29 for the indicators and their 
meanings. 
If there is no call forward sequence programmed, 
an additional two beeps sound after entering this 
mode. These two beeps normally sound after the 
last digit of the call forward sequence is shown. 
3.  Press [STAY][1 2 1] and enter the phone number 
to which you want calls from the control panel 
diverted. 
4.  Press [STAY][2][AWAY]. 
Two beeps sound and the system returns to the 
disarmed state. 
Example 
If you want to automatically divert all incoming calls 
to another telephone number (for example, 9672 
1777) when the system is armed in AWAY Mode, 
enter: 
[1 2 3 4 3][AWAY][1][AWAY][STAY] 
[1 2 1 9 6 7 2 1 7 7 7][STAY][2][AWAY] 
You can suspend the Telco arming sequence at any 
time.  
To disable the Telco arming sequence: 
Enter the Installer Code and press [3][AWAY][1] 
[AWAY][STAY][4][AWAY]. 
To program the Telco disarming sequence – easy 
call forward (immediate off): 
1.  Enter the Installer Code and press [3][AWAY]. 
Three beeps sound and the STAY and AWAY 
indicators flash. 
2.  Press [2][AWAY] to change the Telco disarming 
sequence. 
Three beeps sound.   
If a Telco disarming sequence is already 
programmed, the sequence appears one digit at a 
time using the remote codepad indicators. Refer 
to Table 23 for the indicators and their meanings. 
If there is no Telco disarming sequence 
programmed, an additional two beeps sound after 
entering this mode. These two beeps normally 
sound after the last digit of the sequence appears. 
3.  Press [STAY][2 2 1][STAY][2][AWAY]. 
Two beeps sound and the system returns to the 
disarmed state. 
You can suspend the Telco disarming sequence at 
any time.  
To disable the Telco disarming sequence: 
Enter the Installer Code and press [3][AWAY][2] 
[AWAY][STAY][4][AWAY]. 
6.1.4 
Setting STAY Mode 2 Zones 
This function allows the installer to select the zones 
that are automatically isolated when the system is 
armed in STAY Mode 2.  
To arm the system in STAY Mode 2, press and hold 
[0] until two beeps sound.  
Refer to Section 6.3.3 on page 37 or Section 4.5 Arming 
the System in STAY Mode 2
 on page 17 for more 
information. 
To set STAY Mode 2 zones: 
1.  Enter the Installer Code and press [4][AWAY]. 
Three beeps sound and the STAY indicator 
flashes. 
2.  Enter the number of the zone you want to 
automatically isolate and press [STAY]. 
The corresponding zone indicator flashes. 
3.  Repeat Step 2 for each zone you want to select. 
 
As you select each zone to isolate, the 
corresponding zone indicator flashes. If 
you make a mistake, enter the incorrect 
zone number and press [STAY]. This 
zone is no longer selected to isolate and 
the zone indicator turns off. 
 
4.  Press [AWAY].   
Two beeps sound and the system returns to the 
disarmed state. 
The indicators for the zones you selected and the 
STAY indicator turn off. 
Example 
If you want to select zones 2, 5, and 6, enter: 
[1 2 3 4 4][AWAY][2][STAY][5][STAY][6][STAY] 
[AWAY] 
You can disable all zones selected to automatically 
isolate for STAY Mode 2 at any time.  
To disable STAY Mode 2 zones: 
Enter the Installer Code and press [4][AWAY] 
[AWAY]. 
6.1.5 
Satellite Siren Service Mode 
If the SS914 Satellite Siren (EDMSAT) is connected 
to Output 1, this function allows you to perform 
service work on the system without activating the 
satellite siren. The satellite siren returns to its normal 
working state the next time the system is armed.