Make Electrical Connection
 
 
WARNING: Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating. 
Failure to do so can result in death or electrical shock. 
1.  Disconnect power.
2.  Locate junction box of the range hood.
3.  Remove terminal box cover and set aside.
4.  Remove knockout from terminal box and install a UL 
 
listed or CSA approved ½” strain relief. 
5.  Place the range hood near its mounting position and run the 
 
power supply cable through the strain relief into terminal box 
 
(enough to make connection).
6.  Tighten the strain relief screws.
A
C
B
A. Electric box cover
B. Cover installation screws
C. Knockout
A
B
C
D
E
F
A.White wires
B. Black wires
C. UL listed wire connectors
D. Green, Bare or Yellow/Green wires
E. Home power supply
F. UL listed or CSA approved ½” strain    
 relief
7.  Use UL listed wire connectors and connect black wires (B) 
 together.
8.  Use UL listed wire connectors and connect white wires (A) 
 together.
9.  Connect green (or bare) ground wire from home power supply 
 
to the green/yellow ground wire (D) in terminal box using UL 
 
listed wire connectors.
10. Install terminal box cover.
11. Check that all light bulbs are secure in their sockets.
12. Reconnect power.
Complete Installation and  
Check Operation 
1.  Install grease filters. See the “Range Hood Care” section.
2.  Install heat lamps into heat lamp sockets.
3.  Check operation of the range hood blower and lights. See the 
 
“Range Hood Use” section. 
A
E
D
B
C
 
A. Halogen lamps
 
B. Lamps knob 
 
C. Blower knob
D. Filter handles
E. Grease filter
 
4.  If range hood does not operate, check to see whether a circuit 
 
breaker has tripped or a household fuse has blown.  
 
Disconnect power supply and check that the wiring is correct. 
NOTE: To get the most efficient use from your new range hood, read 