Check Processor Type
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
100
DKAdmin/DKBackup
Check Processor Type
To check processor type
1. Select a customer using the Select Customer option in the File Menu.
2. From the Administration Menu/Backup Menu, press 
c
 to display a pop-up dialog box.
3. Enter the four-digit DK Code. The default is 0000. This is the “first level password” which 
is set in the Strata DK Program 00. The code does not display as you type it.
4. DKAdmin/DKBackup pulls Program 00 and displays the processor type, ROM/Flash 
version and release numbers, along with the same information of the selected customer 
database. Verify that the displayed information is the same as the processor installed in the 
DK system.
Notes
If the PC and Strata DK do not communicate, the Problem: Unable to Establish 
Communications screen appears. Follow the instructions on the screen and/or see 
Appendix A – Connecting to Strata DK
 to correct the problem.
Make sure the programming telephone (station 205 or 213) is not in the programming 
mode.
Backup Data
Prior to backing up
1. Select a customer using the Select Customer option in the File Menu.
Note
Before you can select the customer, you must use the Maintain Customer File option 
to create a customer.
2. Establish a communications path between the PC (running DKAdmin/DKBackup) and the 
Strata DK using the Dial DK option or by making a direct connection to the Strata DK (see 
Appendix A – Connecting to Strata DK
).
3. After connecting the DKAdmin/DKBackup PC to the Strata DK, select the Administration 
Menu/Backup Menu and run the Check Processor Type option to verify that the customer 
file format is the same as the installed Strata DK processor. When checking the processor, 
you must enter the DK code programmed on the installed processor.
Important!
Make sure the processor type, ROM/Flash release number (1~4) are the same as 
the customer database you are backing up. Release 3 and 4.X are considered the 
same for backing up and restoring databases.
If the Problem: Unable to Establish Communications screen displays, follow the steps on 
the screen and/or see 
Appendix A – Connecting to Strata DK
 to correct the problem.
To back up (download) a customer’s database
1. After checking the processor type, select the Administration Menu/Backup Menu and type 
b
. The DK Code dialog displays.
2. Enter the four-digit DK Code (if prompted to do so).
Important!
You must enter the code that is programmed on the installed processor.