Toshiba DK Backup 用户手册

下载
页码 178
Restore Data
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
102
DKAdmin/DKBackup
The DK System Program File list is displayed (see 
Step 3 
on 
Page 101
). If this screen does 
not display, the DKAdmin/DKBackup PC and the Strata DK are not communicating. See 
Appendix A – Connecting to Strata DK
 for procedures to connect the PC COM port to the 
Strata DK PIOU, RSSU, RSIS, RSIU, or PIOUS TTY port, or IMDU or RMDS modems.
Important!
If the PC screen does not display prompts such as 
Turning on LED 10, 
Program 77-1
XXX:LOGGING IN
, etc., the PC and Strata DK are not 
communicating. When operating properly, DKAdmin/DKBackup logs off and on 
in between each program file it restores. If a communication failure exists, see 
Appendix A – Connecting to Strata DK
. If the communication path between the 
PC and Strata DK is broken during Backup or Restore operations, it may be 
necessary to go in and out of the Program mode from the programming telephone 
(Station 205); or turn the Strata DK power off and on to resume communications.
Restore Data
Prior to restoring data
1. Select a customer using the Select Customer option in the File Menu.
This should be the customer database which has been created or previously backed up 
using DKAdmin/DKBackup. This customer database must be the same DK Release
(e.g., 1, 2, 3, or 4.X) and processor type to which you are restoring data.
Although DK16e is considered Release 1, it contains the Release 3 features of RCTUA3 
with the exception of Distributed Hunt.
Note
Release 3 data can be restored to Release 3.X data and vice versa.
2. Establish communications between the DKAdmin/DKBackup PC and the Strata DK using 
the Dial DK option or by making a direct connection (see 
Appendix A – Connecting to 
Strata DK
).
3. After connecting to the Strata DK, select the Administration Menu/Backup Menu and run 
the Check Processor Type option to verify that the customer file format is the same as the 
installed Strata DK processor.
Important!
 Make sure the processor type, ROM/Flash release number is the same as the 
customer database you are restoring.
If the Problem: Unable to Establish Communications screen displays, follow the steps on 
the screen and/or see 
Appendix A – Connecting to Strata DK
 to correct the problem.
To restore (upload) a customer’s database
1. After checking the processor type, select the Administration Menu/Backup Menu and type 
b
. The DK Code dialog displays.
2. Enter the four-digit DK Code (if prompted to do so).
Important!
You must enter the code that is programmed on the installed processor.
For security, this code does not display on screen as you type it. The default code is 0000. 
This is the “1st level password” which is set in the Strata DK system Program 00 (see the 
record sheet for Program 00 in the Strata DK Programming Manual).