6. APPLICATION FUNCTIONS 
 
6.16 Completion of operation signal 
The completion of operation signal (OPF) shows a completion of operation status. At the startup, the 
"completion of operation signal" (OPF) turns off, and the "completion of operation signal" (OPF) turns on when 
positioning operation is complete. 
Interruption of operation due to an alarm also turns on the completion of operation signal (OPF). 
A summary of operation for each operation mode is shown. 
 
API LIBRARY  
Use the sscWaitIntDriveFin/sscGetDriveFinStatus function to check the 
completion of operation. 
 
 
(1) Using a JOG operation 
ON
OFF
ON
OFF
ON
OFF
Speed
Start operation (ST)
During operation (OP)
During smoothing of
stopping (SMZ)
ON
OFF
In-position (INP)
ON
OFF
Completion of 
operation (OPF)
Start of operation
Stop operation
 
 
(2) Using incremental feed 
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Operation is stopped after 
the movement amount
designated by the incremental 
feed movement amount is moved.
Speed
Start operation (ST)
During operation (OP)
During smoothing of
stopping (SMZ)
In-position (INP)
Completion of 
operation (OPF)
Start of operation