3M 2273M Benutzerhandbuch

Seite von 66
 40 
78-8130-6150-0 Rev G
 
− The receiver display will add the Alert bar 
graph and the type of marker to the display 
with a prompt to adjust the marker gain.
4.  Press the Gain [4] until only a small mark on 
the marker bar graph is visible.
5.  Press Locate/OK [5] to save the marker gain 
setting.
 
− The display will return to Special Peak Cable 
Locate / Alert On.
 
− If the selected type of utility marker is 
detected, a second audio tone will emit from 
the unit and the marker bar graph will fill. 
The marker utility will default to the last 
type of marker set in marker locate mode.
6.  Press Locate/OK [5] + Marker [SK] + Marker 1 
[SK Toggle] to change the type of marker that 
the unit will detect in alert mode.
7.  Press Locate/OK [5] and then Cable/Pipe [SK] 
to return to the locate mode with the newly 
selected marker type now visible on the display. 
Adjust the Gain [4] again (per Step 4 above) 
and then press Locate/OK [5].
C. Single Marker Locate
1.  Press Locate/OK [5]
2.  Press Marker [SK]
3.  Press Markr 1 [SK Toggle] to select desired 
utility.
4.   Markr 2 should be OFF.
Note: Only the marker types enabled in the setup 
menu will be shown. (See Enabling/Disabling 
Marker types, Section 13A). When scanning for 
markers, the gain level [12] should be set high.
 
− When a marker is detected, adjust the Gain 
[4] down until the bar graph opens.
 
− The bar graph will close, the audio will 
be steady, and the Signal Strength will be 
maximum when the receiver detects a marker 
of the specified utility and has pinpointed its 
location.