Epson S1D13708 Benutzerhandbuch

Seite von 574
Epson Research and Development
Page 51
Vancouver Design Center
Programming Notes and Examples
S1D13708
Issue Date: 01/11/20 
X39A-G-003-01
ADVANCE
D
 IN
FOR
MAT
ION
Subje
ct to C
ha
nge
8.3.2   SwivelView 90°
Figure 8-3: Picture-in-Picture Plus with SwivelView 90° enabled
SwivelView 90
°
 is a mode in which both the main and PIP
+
 windows are rotated 90
°
 
counter-clockwise when shown on the panel. The images for each window are typically 
placed consecutively, with the main window image starting at address 0 and followed by 
the PIP
+
 window image. In addition, both images must start at addresses which are dword-
aligned (the last two bits of the starting address must be 0).
Note
It is possible to use the same image for both the main window and PIP
+
 window. To do 
so, set the PIP
+
 Line Address Offset register (REG[81h],REG[80h]) to the same value 
as the Main Window Line Address Offset register (REG[79h],REG[78h]).
PIP+ window
main-window
PIP+ window y start position
panel’s origin
PIP+ window y end position
PIP+ window x start position
PIP+ window x end position
90° SwivelView
TM
(REG[8Dh],REG[8Ch])
 (REG[85h],REG[84h])
 (REG[89h],REG[88h])
 (REG[91h],REG[90h])