DIAGNOSTIC LOG 
 
Displayed Message  
Explanation of Condition 
KEY STUCK 
A key on the user keypad has been closed continuously for >15 
seconds 
WATER LEAKAGE   
The hot inlet valve has had to be switched on > 30 times since 
the last vend was taken 
NO CUPS      
Comes into force after 2 unsuccessful attempts to drop a cup 
ELECTRONICA 
Internal serial communication failure between the control board 
and the RIO board 
IO CONFIG ERR.    
Board has not been initialized using the ENG LINK 
WASTE TRAY FULL 
Either the Liquid or Coffee ground waste bucket is full of water 
HEATER INHIBITED 
The heater tank has not filled within the 3.5 minute time limit 
PLACE OWN CUP   
Sold-out of cups 
FILLING BOILER 
Comes into force 15 seconds after starting to fill the heater tank 
with water. Indication of a slow rate of fill 
C BREWER FAULT 
Brewer unit is not cycling correctly – a motor or cycle-switch fault  
NEW FILTER REQD 
Filter belt warning (if activated) – comes into force after air 
pressure seen to be present after 7 seconds 
FILTER BROKEN   
Brewer Fault – comes into force after air pressure has seen to be 
present after 20 seconds during a vend 
DOOR FAULT    
Cup door mechanism is not cycling correctly - a motor or cycle-
switch fault 
 
NOTES: 
1) 
The event log will only record events that persist for two or more consecutive event log checks. Event 
log checks take place once every 60s, so in the worst case scenario an event may have to be in force 
for almost 120s before it is recorded. 
2) 
The event log does not handle concurrent events. If two (or more) fault conditions are active, only the 
first occurrence will be recorded.