Bypassing Protection Zones (cont’d) 
Zones Remaining Bypassed After Disarming 
The system provides an option to allow all manually bypassed zones to remain 
bypassed upon disarming (security code + OFF) of the partition. This option must be 
programmed by your installer.  Check with your installer to see if this option has been 
enabled.    
NOTES: 
For each partition in which the option is enabled, the security code + OFF will no 
longer unbypass zones.  To unbypass ALL zones you must enter your security code + # 
+ 64.  To unbypass zones INDIVIDUALLY, you must enter your security code + 6 + 
zone number. 
Any zone that was automatically bypassed by the system will be unbypassed upon 
disarming the system (e.g. STAY mode, Auto-STAY, etc.).  
Vent zones and zones bypassed by a programmed Auto-Bypass schedule (Tme Driven 
Event) are considered “manual bypasses” and will not be unbypassed upon disarming 
the system. 
Zones that were in a bypassed state at the time a System Shutdown is sent from the 
Compass Downloading software will be unbypassed when the System Shutdown is 
removed.