Honeywell 128BPTSIA Benutzerhandbuch

Seite von 80
 
 
– 33 – 
Arming Perimeter Only 
(With Entry Delay ON) 
Using the   3   STAY key 
Use this key when you are staying home, but might expect someone to use 
the entrance door later. 
When armed in STAY mode, the system will sound an alarm if a protected 
door or window is opened, but you may otherwise move freely throughout the 
premises. Late arrivals can enter through the entrance door without causing 
an alarm, but they must disarm the system within the entry delay period or 
an alarm will occur.  
The system provides three STAY modes. STAY mode 1, 2, and 3. STAY 
modes 1 and 2, when activated automatically bypass specific zones assigned 
by your installer to each of the STAY modes. If there are only Stay 1 zones, 
entering Code+Stay[3] will automatically arm in Stay Mode 1; however if 
there is at least one zone assigned to Stay Mode 2, you MUST enter either 
Code+[3]+[1], Code+[3]+[2] or Code+[3]+[3], else the panel will not arm. If 
Code+[3] is entered Stay Mode 1 prevails (even if there are Stay Mode 2 
zones). Check with your installer for a list of the zones that are bypassed 
during each STAY mode. 
Close all perimeter windows and doors before arming (see 
CHECKING FOR OPEN ZONES section)
 
 
 
STAY 
1.  Enter your security code and press  
  +   1   for STAY Mode 1. 
 
Enter your security code and press  
  +   2   for STAY Mode 2. 
 
Enter your security code and press  
  +   3   for STAY Mode 3. 
2. 
ARMED ***STAY 1* 
ZONE BYPASSED 
The keypad beeps three times, displays the 
armed message, and indicates which STAY 
mode (1, 2 or 3). 
Note: "ZONE BYPASSED" in this display 
simply indicates that some zones of protection 
are not armed when using STAY mode.