Zn 
  
ZT  P  RC  IN:  L 
10    00  1 10   RF 
  
 
Zone Programming 
ZT = see Zone Type chart 
shown in *56 Menu 
Mode “Zone Type” 
prompt 
P =  partition 1, 2, 3 
(common);  
RC = 1 (send CID report); 0 
(no report) 
IN =  input type;  
L =  loop number 
[
∗] to continue
 
 
A summary screen with the selected zone’s current 
programming appears.  
Begin programming zone information as follows: 
•  Enter Zone Type (ZT), Partition (P), Report Code (RC; 0-9 
only; use *56 mode to enter hex codes), and Input Device 
Type (IN)* sequentially, but not the Loop No. (L). 
•  Use the [A] (Advance) and [B] (Back) keys on the keypad to 
move the cursor within the screen. 
•  Use the [C] key to copy the previous zone’s attributes. 
 
 
Press [
✱] to save the programming and continue to the serial 
number/loop number prompt. If needed, you can press the [#] 
key to back up without saving. 
* If HW (hardwired) or AW (Auxiliary) is entered for Input Device 
Type, the next screen will be similar to the prompt shown, except 
that HW or AW will be displayed under “IN”. 
If RF, BR, or UR is entered, a prompt for Serial and Loop 
number will be displayed, as described in 
∗56 Menu mode 
section. 
When done, the display returns to the initial summary screen 
prompt to let you program the next zone. 
To exit this mode, enter 00 at the Summary Screen prompt.
 
 
 
WIRELESS KEY PROGRAMMING TEMPLATES  
(press the [D] key from *58 Menu mode Summary Screen) 
This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user 
number
 (see 
System Operation section, Assigning Attributes Command in the User Guide). 
 
 
 
 
TEMPLATE  ? 
1–6 1 
 
Template Number 
1–3 = 5804 templates; 4–6 
= 5804BD templates 
 
•  Enter Template number 1–6 (see chart on next page).  
 
See the defaults provided for each template in the chart that 
follows these procedures. 
•  Select from templates.  Press [∗] to display template (1 
shown selected).   
NOTE: If necessary, press [#] to back up and re-enter 
template number. 
•  Press [#] if you want to return to *58 Menu mode summary 
screen.
 
 
 
 
L    01    02    03   04 
T    23    22    21  
 
23 
 
Template Display 
 
• When 
[
∗] is pressed, the selected template will be displayed. 
 
Top line of display represents loop numbers; bottom line 
represents zone type assigned for each loop. 
• Press 
[
∗] to accept template.
 
 
 
 
PARTITION 
 1 
 
Partition 
FA168CPS. 1 = partition 1; 
2 = partition 2 
 
•  Enter the partition in which the key is to be active, then press 
[
∗] to continue.
 
 
 
 
ENTER START ZONE 
00 = QUIT 
 36 
 
Start Zone Number 
 
•  The system will search for the highest available consecutive 
4-zone group (the four zones in the case of the 5804 and 
5804BD), and display the lowest zone number of the group. 
 
If you want to start at a different zone, enter the zone desired, 
and press [
✱]. If that zone number is displayed, the system 
has the required number of consecutive zones available, 
beginning with the zone you entered.  If not, the system will 
again display a suggested zone that can be used.  
If the required number of consecutive zones is not available 
at all, the system will display “00”.  
 
To quit this mode and return to *58 Menu mode, enter 00 at 
this prompt. 
 
• Press 
[
∗] to accept.
 
 
 
 
INPUT S/N             L 
AXXX-XXXX          – 
 
Serial Number 
 
•  Manually enter the serial number printed on the label for the 
wireless key or press and release the button to transmit its 
serial number. 
• Press 
[
∗] to accept the serial number.  The system will check 
for a duplicate. 
•  If necessary, press the [#] key to back up without saving, and 
re-enter the serial number. 
•  Use the [A] key to move forward within the screen, and the 
[B] key to move backward.