– 3 –
352*5$00,1*)250
Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Entries shown in dashed boxes indicate partition entries for FA168C only (not applicable for FA148CP).
Field     Function                                                   Data Entries                      Programmable Values                                           
SYSTEM SETUP (
20–
29)
 20 INSTALLER CODE
    |    |    |      [4112]
4 digits, 0–9
21
QUICK ARM ENABLE
      
      [0,0]
Part. 1 Part.2
0 = no; 1 = yes
22
RF JAM OPTION
       [0]
0 = no RF Jam detection; 1 = send RF Jam report
 UL: must be 1 if wireless devices are used
23
FORCED BYPASS
      
      [0,0]
Part. 1 Part. 2
0 = none  UL: must be “0”
1 = bypass open zones
 24 RF HOUSE ID CODE
   |           |            |     
Part. 1  Part. 2   Common
00 = disable all wireless keypad usage
01–31 = using 5827, 5827BD or 5804BD keypad
[00,00,00]
26
CHIME BY ZONE
       [0]
0 = no; 1 = yes  (select zones to chime on zone list 3,
using *81 Menu mode)
27
X–10 HOUSE CODE
      
[0]
0 = A;  1 = B, 2 = C, 3  = D, 4 = E, 5  = F, 6 = G,
7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N,
 #14 = O, #15 = P UL: not for fire or UL installations
28
ACCESS CODE FOR
4285/4286 PHONE MODULE
   |      [00]
(Partition 1 only)
00 = disable; 1st digit: enter 1–9; 2nd digit: enter # + 11
for "
", or # + 12 for "#".
 UL: must be “00” for UL Commercial Burg. installations
 29 LONG RANGE RADIO OUTPUT
       [0]
0 = disable; 1 = enable
ZONE SOUNDS AND TIMING (
31 – 
39)
31
ONE AUDIBLE ALARM PER ZONE
        [0]
0 = no  UL: must be “0”; 1 = yes
32
FIRE ALARM SOUNDER TIMEOUT
         [0]
0 = sounder stops at timeout;
1 = no sounder timeout UL: must be “1” for fire install.
33
ALARM SOUNDER TIMEOUT
         [1]
0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min;
4  = 16 min;  UL: minimum “1” (4 min.)
34
EXIT DELAY
   |           |       [70,70]
Part. 1
Part. 2
00–99 = seconds of exit delay time for each partition
Common zones use same delay as partition 1.
35
ENTRY DELAY #1 (zone type 01)
   |            |      [30,30]
Part. 1
Part. 2    
 
00–99 = seconds of entry delay #1 time for each
partition;  UL: 45 seconds max.
Common zones use same delay as partition 1.
36
ENTRY DELAY #2 (zone type 02)
   |           |      [60,60]
Part. 1
Part. 2
00–99 = entry delay #2 time for each partition;
UL: 60 seconds max.
Common zones use same delay as partition 1.
 37 AUDIBLE EXIT WARNING
      
      [1,1]
Part. 1
Part. 2
0 = no; 1 = yes
38
CONFIRMATION OF ARMING DING
      
      [0,0]
Part. 1
Part. 2 
0 = no; 1 = yes (wired keypads and RF)
2 = yes, RF only
39
POWER UP IN PREVIOUS STATE
        [1]
0 = no; 1 = yes  UL: must be “1”
DIALER PROGRAMMING (
40 – 
42)
Enter the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '
'; #+12 for '#'; #+13 for a 2-second pause. If fewer than the
maximum digits entered, exit the field by pressing [
] and next desired field number.
 40 PABX ACCESS CODE
    |     |     |    |    |    
Enter up to 6 digits. To clear entries from field, press 
40
 .
 41 PRIMARY PHONE No.
     |      |     |     |      |     |     |     |     |     |     |     |     |     |     |     |     |     |     |       
Enter up to 20 digits. To clear entries, press 
41
 .
 42 SECOND PHONE No.
     |      |     |     |      |     |     |     |     |     |     |     |     |     |     |     |     |     |     |       
Enter up to 20 digits. To clear entries, press 
42
 .