Avaya 03-300430 Benutzerhandbuch
Communication Manager Maintenance-Object Repair Procedures
1452 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
maint/FE
WRN
Signaling channel has
been down for over 90
sec.
Consult ISDN-SGRP and/or
ISDN-LNK. Far-end signaling
channel may be busied out, or the
far-end switch may currently be
restarting.
WRN
Repeated failure of far
end to respond to
messages.
Maintenance software will
periodically try to resend
messages. You can speed the
process with test trunk grp#/
mem# and/or test
signaling-group sig-grp#.
WRN
The far-end trunk is
being tested.
Check status of the far-end switch.
Wait for testing to finish.
in-service
None
Normal operating state
1. ISDN-TRK alarms; alarms against other objects may also be present.
Table 520: Service States (continued)
Service State
Alarm
1
Possible Cause
Possible Solution
2 of 2
Table 521: DS1 ISDN Trunk Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
0
Any
Any
Any
test port location
Any
None
test port location
15 (
)
Any
Audit and Update Test
(#36)
18
0
busyout trunk
grp#/mem#
release trunk grp#/mem#
19 (
0
None
129 (
None
WRN
OFF
test port location
130 (
None
WRN
ON
test port location
257 (
Any
None
test port location
1 of 2