Avaya 03-300430 Benutzerhandbuch
MG-DS1 (DS1 Interface Media Module)
Issue 1 June 2005
1605
SAKI Sanity Test (#53)
!
CAUTION:
CAUTION:
This test resets the Media Module. The test is highly destructive and can only be
initiated by a system technician-demanded reset board location
initiated by a system technician-demanded reset board location
command.
Table 591: Test #53 SAKI Sanity Test
Error
Code
Code
Test
Result
Result
Description/ Recommendation
None
ABRT
System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum
of 5 times.
1005
ABRT
Wrong Media Module configuration to run this test. This error applies
only to DS1 Interface Media Modules. It means the DS1 Interface Media
Module is providing timing for the system, and therefore, it cannot be
reset without major system disruptions.
only to DS1 Interface Media Modules. It means the DS1 Interface Media
Module is providing timing for the system, and therefore, it cannot be
reset without major system disruptions.
1. If the Media Module needs to be reset, then set synchronization to
another DS1 Interface Media Module or to the Tone-Clock Media
Module and try again.
Module and try again.
1015
ABRT
Port is not out-of-service.
1. Busyout the Media Module.
2. Execute the reset board command again.
2100
ABRT
System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a maximum
of 5 times.
1
FAIL
The Media Module failed to reset.
1. Execute the reset board command again.
2. If the problem persists, replace the Media Module.
2. If the problem persists, replace the Media Module.
2
FAIL
The Media Module failed to restart.
1. Execute the reset board command again.
2. If the problem persists, replace the Media Module.
2. If the problem persists, replace the Media Module.
1 of 2