Avaya 03-300430 Benutzerhandbuch
Communication Manager Maintenance-Object Repair Procedures
2212 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Table 789: Test #618 BRI Port Local LAN Loop Around
Error
Code
Code
Test
Result
Result
Description / Recommendation
1015
ABRT
The port is not out-of-service.
1. Use status bri-port location to determine the status of
the port.
2. If it is in use, wait until it is idle, and then use busyout port
location to place it in the out-of-service state and repeat this
test.
!
CAUTION:
CAUTION:
Since the busyout command is destructive, execution
of this command prior to the port being idle causes
every call associated with the BRI port to be torn
down.
of this command prior to the port being idle causes
every call associated with the BRI port to be torn
down.
1139
ABRT
The Packet bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet bus.
2. Run test port location long and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test
(#618).
(#618).
1141
ABRT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Run test port location long and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test
(#618).
(#618).
1144
ABRT
The Processor Port Network Packet Bus is out-of-service
1. Follow the repair procedures for the Packet Bus.
2. Run the test port location long and verify the repair by
viewing the results of the BRI Port Local LAN Loop-Around test
(#618).
(#618).
S8300
/
G700
:
1412
ABRT
This test does not execute on a G700 media gateway.
2012
2100
ABRT
Internal system error
Could not allocate the necessary system resources to run this test.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 2