Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2212 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 789: Test #618 BRI Port Local LAN Loop Around 
Error
Code
Test
Result
Description / Recommendation
1015
ABRT
The port is not out-of-service.
1. Use status bri-port location to determine the status of 
the port.
2. If it is in use, wait until it is idle, and then use busyout port 
location to place it in the out-of-service state and repeat this 
test.
!
CAUTION:
CAUTION:
Since the busyout command is destructive, execution 
of this command prior to the port being idle causes 
every call associated with the BRI port to be torn 
down.
1139
ABRT
The Packet bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet bus.
2. Run test port location long and verify the repair by 
viewing the results of the BRI Port Local LAN Loop-Around test 
(#618).
1141
ABRT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Run test port location long and verify the repair by 
viewing the results of the BRI Port Local LAN Loop-Around test 
(#618).
1144
ABRT
The Processor Port Network Packet Bus is out-of-service
1. Follow the repair procedures for the Packet Bus.
2. Run the test port location long and verify the repair by 
viewing the results of the BRI Port Local LAN Loop-Around test 
(#618).
S8300
 / 
G700
:
1412
ABRT
This test does not execute on a G700 media gateway.
2012
2100
ABRT
Internal system error
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2