Alarms in Linux Media Servers
Issue 1 June 2005
89
UPS (Uninterruptible Power Supply)
S8700 | 8710
/
S8500
/
S8300
The UPS MO supports the UPS device for each media server. This MO’s maintenance software
reacts to UPS-generated in-line errors via SNMP traps.
reacts to UPS-generated in-line errors via SNMP traps.
Note:
Note:
This MO provides no periodic or on-demand tests.
UPS Traps to Media Server
on page 89 contains the various
UPS-generated SNMP traps to the media server.
Table 25: Enterprise-Specific UPS Traps to Server
SNMP Trap from UPS
Event
ID
ID
Definition of Trap
Trap (1)
#6
(
(
Alarm string = #1, ACT, UPS, A, 6, MAJ, power failure:
Shutting down in 6 minutes.
If the Event ID is 6, the UPS battery’s power is in a
If the Event ID is 6, the UPS battery’s power is in a
critically low condition, with an estimated 6 minutes of
remaining holdover.
●
A warning is written to every logged-in user of the
server.
server.
●
When 6 minutes elapse, the server begins shutting
down.
down.
(For troubleshooting procedures, see Events #
Trap (1)
#7
(
(
Alarm string = #1, ACT, UPS, A, 7, MAJ, power failure:
Shutting down in 7 minutes.
The UPS battery’s power is in a critically low condition,
The UPS battery’s power is in a critically low condition,
with an estimated 7 minutes of remaining holdover.
●
A warning is written to every logged-in user of the
server.
server.
●
When 7 minutes elapse, the server begins shutting
down.
down.
(For troubleshooting procedures, see Events #
1 of 4