Avaya 03-300430 Benutzerhandbuch
EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005
1229
2100
ABRT
Could not allocate the necessary system resources to run this test.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
ANY
FAIL
The transmitted data packet was not received correctly by the Packet
Interface circuit pack. The failure may be in the EI under test, the DS1
converter circuit packs, or the intervening Center Stage components.
Interface circuit pack. The failure may be in the EI under test, the DS1
converter circuit packs, or the intervening Center Stage components.
1. Test the Packet Interface circuit with test packet-interface CS
where “C” is the IPSI’s carrier in a high- or critical-reliability system, and
“S” is the slot number where the IPSI’s Packet Interface resides. If the
Packet Interface circuit fails any tests, see
“S” is the slot number where the IPSI’s Packet Interface resides. If the
Packet Interface circuit fails any tests, see
2. If the EI under test resides in a high-reliability system’s PN,
(2 PN-to-CSS fibers in an unduplicated PNC), run the short test
sequence on both of the PN’s EI boards, and follow procedures for
Test #589.
sequence on both of the PN’s EI boards, and follow procedures for
Test #589.
3. Enter display errors and resolve any PKT-BUS errors.
4. Perform the
4. Perform the
in
in Maintenance Procedures (03-300192).
PASS
Although this test has passed, there may be related problems on other EIs
used in connectivity to and from this EI. Software may have conducted
tests on these other components and determined that this board was
functioning properly and any problems were probably due to a problem with
some other connectivity component. Check the error and alarm logs for
problems with other EI circuit packs and resolve these errors.
used in connectivity to and from this EI. Software may have conducted
tests on these other components and determined that this board was
functioning properly and any problems were probably due to a problem with
some other connectivity component. Check the error and alarm logs for
problems with other EI circuit packs and resolve these errors.
1. Refer to other EI board tests if the link is not functioning correctly.
0
NO
BOARD
No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use reset board
location.
location.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 416: Test #589 Expansion Interface Packet Interface Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
5 of 5