Avaya 03-300430 Benutzerhandbuch
Communication Manager Maintenance-Object Repair Procedures
1834 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1336
ABRT
Internal system error.
1. Use set ipserver-interface location to make the standby
Packet Interface active.
2. Run the test.
1337
ABRT
The test is not allowed to run because a PNC interchange is in progress. A
PNC interchange may have been initiated with reset pnc
interchange, or as part of a recovery action.
PNC interchange may have been initiated with reset pnc
interchange, or as part of a recovery action.
1. Wait 3 minutes and retry the command.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABRT
Internal system error
1. Retry the command.
NO
BOARD
The IPSI circuit pack’s Packet Interface module is assigned, but is not
detected as physically present.
detected as physically present.
1. If the IPSI circuit pack is present, replace it.
2. If the IPSI circuit pack is not present, insert a TN2312AP IPSI circuit
pack in the assigned slot, and rerun the test.
Table 673: Test #888 Active-Standby Peer Link Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 3